BibliotecaPortal de investigación
es | gl
  • Home
  • Contact us
  • Give feedback
  • Help
    • About Investigo
    • Search and Find
    • Submit
    • Intellectual Property
    • Open Access Policy
  • Links
    • Sherpa / Romeo
    • Dulcinea
    • OpenDOAR
    • Dialnet Plus
    • ORCID
    • Creative Commons
    • UNESCO Nomenclature
    • español
    • English
    • Gallegan
JavaScript is disabled for your browser. Some features of this site may not work without it.
All of InvestigoAuthorsTitles Materias Unesco Research GroupsType of ContentsJournal TitlesThis CollectionAuthorsTitlesUNESCO SubjectsResearch GroupsType of ContentsJournal Titles

Library guides

Self-archivingRequest PermissionRelated guides

Statistics

View Usage Statistics

Tuning of synchronous-frame PI current controllers in grid-connected converters operating at a low sampling rate by MIMO root locus

Freijedo Fernández, Francisco DanielAutor UVIGO; Vidal González, AnaAutor UVIGO; Gómez Yepes, AlejandroAutor UVIGO; Guerrero, Josep M; López Sánchez, ÓscarAutor UVIGO; Malvar Álvarez, JanoAutor UVIGO; Doval Gandoy, JesúsAutor UVIGO
DATE: 2015-08
UNIVERSAL IDENTIFIER: http://hdl.handle.net/11093/7371
EDITED VERSION: http://ieeexplore.ieee.org/document/7036121/
UNESCO SUBJECT: 33 Ciencias Tecnológicas
DOCUMENT TYPE: article

ABSTRACT

Current controller performance is key in gridconnected power converters for renewable energy applications. In this context, a challenging scenario is arising in multi-megawatt wind turbines, where sampling and switching frequencies tend to be lower and lower as power ratings increase. This strongly affects achievable control time constant. With this perspective, this paper presents a systematic procedure for accurate dynamics assessment and tuning of synchronous-frame proportional–integral current controllers, which is based on linear control for multiple-input–multiple-output (MIMO) systems. The dominant eigenvalues of the system are calculated with explicit consideration of time-delay and cross-coupling terms, two factors which clearly impair the system dynamics when considering a low sampling frequency. The proposed methodology is summarized as follows. First, the plant and controller matrices are modeled in state space. Subsequently, the characteristic polynomial of the closed-loop system is obtained and a computer-aided parametric analysis is performed to calculate the MIMO root locus as a function of the control gain. By its inspection, it is possible to identify the gain, which minimizes the current closed-loop time constant. This tuning is suitable for wind turbine applications, taking into consideration cascaded-control structures and grid-code requirements. The validity and accuracy of the analysis is fully supported by experimental verification.
Show full item record

Files in this item

[PDF]
Name:
2015_gomez_tuning_mimo.pdf
Size:
1.481Mb
Format:
PDF
Description:
Manuscrito aceptado
View/Open

Send to

MendeleyZoteroRefworks

The Institutional Repository of the University of Vigo Investigo is disseminated in:

University library
Rúa Leonardo da Vinci, s/n
As Lagoas, Marcosende
36310 Vigo

Location

Information
+34 986 813 821
investigo@uvigo.gal

Accessibility | Legal notice | Data protection
Logo UVigo

INFORMACIÓN
+34 986 812 000
informacion@uvigo.gal

CONTACTO

CAMPUS DO MAR

CAMPUS DE OURENSE
+34 988 387 102
Campus da Auga

CAIXA DE QUEIXAS, SUXESTIÓNS E PARABÉNS

TRANSPARENCIA

CAMPUS DE PONTEVEDRA
+34 986 801 949
Campus CREA

OUTRAS WEBS INSTITUCIONAIS

EMERXENCIAS

CAMPUS DE VIGO
+34 986 812 000
Campus Vigo Tecnolóxico

MURO SOCIAL