Experimental evaluation of the effect of ozone treatment on the oxidation and removal of dry soot deposits of the exhaust gas recirculation system
DATE:
2023-07
UNIVERSAL IDENTIFIER: http://hdl.handle.net/11093/6749
EDITED VERSION: https://linkinghub.elsevier.com/retrieve/pii/S2405844023050697
DOCUMENT TYPE: article
ABSTRACT
The integration of alternative energy sources as a replacement for fossil fuels across various industrial sectors, including power generation, emergency systems, or marine applications, is uncertain. As a result, the utilization of traditional fuels is not anticipated to be fully phased out in the near future. To address this, new technologies, such as those that employ oxidising atmospheres, have been explored as a means to enhance the pollution control capabilities of existing technologies, as the Exhaust Gas Recirculation (EGR) system. In this regard, the present study has assessed the efficacy of ozone atmosphere exposure in mitigating the formation of undesired fouling deposits within the system, with the aim of facilitating more efficient operation of EGR devices and extending their service life. To this end, dry soot samples have been exposed to various ozone atmospheres at different temperatures and ozone concentrations through the utilization of an experimental test bench. The oxidation potential of these atmospheres has been evaluated through the analysis of the deposit mass loss. Likewise, confocal microscopy techniques have been employed to obtain the 3D topography of the fouling samples before and after the ozone treatment, allowing the assessment of the deposit thickness reduction, as well as the surface roughness variation. Additionally, thermogravimetric analysis has been conducted to examine the effects of the oxidation processes on fouling samples composition. The findings of this study have revealed that ozone atmospheres have been effective in reducing deposit mass at ozone treatment temperatures above 100 °C. The reduction in mass has reached 78.5% and 91.8% with treatment temperature of 140 °C with ozone concentrations of 30 gO3/m³ and 50 gO3/m³, respectively. It has also been established that treatment conditions with ozone concentrations of 30 gO3/m³ and 50 gO3/m³ are effective in reducing the thickness of deposits even at intermediate treatment temperatures, resulting in a thickness reduction of 78.6% and 81.1% at 80 °C, respectively. Additionally, it has been observed that the ozone exposure leads to the increase in the proportion of volatile material within the deposi